Battery Charging

  1. Plug the included power cable into the charger and plug it into an outlet

  2. Press the power button on the side of the battery charger to power on the unit

  3. Adjust the charge mode dial to one of three options: Trickle, Standard, & Fast. Trickle is recommended if the timing isn't an issue

  4. Uncap the battery and plug it into either side of the charger

  5. Once connected, the battery will start a countdown of ten seconds, after which it will begin charging automatically

  6. Cell voltages and battery levels are indicated on the LCD screen

  7. When the battery is fully charged, each individual voltage should be about 4.30 Volts. the charger will also display "Fully Charged"

  8. If a partially charged battery is needed, first power down the charger by pressing the 'On/Off' button, then unplug the battery to avoid an error message displayed on the screen



Balancing Instructions

  1. Once every 10 cycles, or whenever red triangular lights are lit up on the battery, a balanced charge is recommended to make all cell voltages the same

  2. When the battery is connected to the charger, individual cell voltages will be displayed on the LCD screen

  3. Connect each end of the black balance cable to the corresponding balance ports on the unplugged battery & powered-on charger.

  4. Follow the standard charging instructions above to conduct a balanced charge



Storage Mode

  1. If a battery will be shipped or will not be used for long periods of time, it is highly recommended that the battery be placed into storage mode

  2. Depending on the current battery percentage, placing the battery into storage mode will either charge or discharge the battery to a voltage that is most stable for shipping and sitting for long periods of time

  3. Plug the main connector into the charger and hold the storage button for 3 seconds during the 10-second countdown

  4. The charger will beep, fans will spin, and the LCD screen will indicate that storage mode has begun.


Troubleshooting

  • If an error message appears on the LCD screen, unplug the battery and press the 'Charge" button to reset the interface.